After-sales Service: | Lifetime Technical Service |
---|---|
Warranty: | 1 Year |
Condition: | New |
Certification: | ISO, CE |
Automation: | Semi-Automatic |
Screw: | Multi-Screw |
Customization: |
---|
Suppliers with verified business licenses
Applicable hospital size (number of beds) |
200-300beds |
Burning Ability | 60-100kg/ times (daily incineration3-6 times) |
Size of the Burner | 1.86m×1.4m×3.4m |
Volume of the Burner |
Gasificationroom1.0m3,secondary bumingroom0.5m3,drift a long buming a room0.06m3 |
Size of the filling entrance | 800mm×900mm |
Chimney | Height 10m out-radius¢300mm |
Blower | Power 0.75kw |
Combustion-support combustion machines | Power 0.11kw,fuelconsumption5.1-10kg/h |
Re-burning machine | Power 0.25kw,fuelconsumption10-20kg/h |
Running voltage | 220V |
Weight | About7000kg |
Target Refuse type |
Burner's temperature |
Smoke's stay time |
Burning rate |
Destroying rate |
Ashes' heat decreasing rate |
Clinical refuse | ≥850 | ≥2.0 | ≥99.9 | ≥99.9 | ≥95 |
Ordinal Numer | Refuse name | Measuring unit | GB18484-2001 |
1 | Blackness of Flue Gas | Ringelmann class | 1 |
2 | Smoke&Dust | mg/m3 | 100 |
3 | CO | mg/m3 | 100 |
4 | SO2 | mg/m3 | 400 |
5 | HF | mg/m3 | 9.0 |
6 | HCL | mg/m3 | 100 |
7 | NO2 | mg/m3 | 500 |
Suppliers with verified business licenses