Customization: | Available |
---|---|
After-sales Service: | Lifetime Technical Service |
Warranty: | 1 Year |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
The main characteristics and scope of application of incinerator
LDF series medical waste incinerator is a medical waste incineration equipment with independent intellectual property rights developed by Shandong Lvdu Environmental Equipment Co., LTD., which introduced the world's advanced medical incinerator technology and organized technical experts to tackle key problems. The equipment has the characteristics of full closure, small size, high incineration efficiency, reasonable process, leading technology, and high degree of harmfulness. It is an ideal garbage disposal equipment for all kinds of hospitals, hotels, stations, large commercial institutions, enterprises, and public institutions. Main features:type project |
LDF-20 | LDF-30 | LDF-50 | LDF-150 | LDF-300 | LDF-500 |
Incineration capacity |
10-20kg/times(can be burned 3-6times per day) | 20-30kg/times(can be burned 3-6times per day) | 30-50kg/times(can be burned 3-6times per day) | 100-150kg/times(can be burned 3-6times per day) | 200-300kg/times(can be burned 3-6times per day) | 300-500kg/times(can be burned 3-6times per day) |
Incineration size m(L×H×B) |
1.6×1.3×1.75 |
1.45×0.9×2.45 |
1.8×1.15×3 |
2×1.5×3.5 |
2.25×1.6×3.8 |
3×2×4.8 |
Garbage inlet size(mm) | 380×480 |
480×600 |
620×800 |
760×960 |
900×1100 |
1080×1280 |
chimney(External diametermm) |
Ø280 |
Ø280 |
Ø280 |
Ø300 |
Ø400 |
Ø460 |
Induced draft fan |
0.25kw |
0.37kw |
0.37kw |
0.5kw |
0.75kw |
0.75kw (Two sets) |
Burner#1 |
power0.11kw Fuel consumption4-6kg/h |
power0.11kw Fuel consumption4-6kg/h |
power0.11kw,Fuel consumption4-10kg/h |
power0.11kw, Fuel consumption4-10kg/h |
power0.22kw, Fuel consumption7-14kg/h |
power0.22kw, Fuel consumption7-14kg/h |
Burner#2 |
power0.11kw Fuel consumption4-10kg/h |
power0.11kw Fuel consumption7-14kg/h |
power0.11kw Fuel consumption7-14kg/h |
power0.22kw Fuel consumption10-20kg/h |
power0.37kw Fuel consumption14-26kg/h |
power0.37kw Fuel consumption20-30kg/h |
Running voltage |
220V |
220V |
220V |
220V |
220V |
220V |
Weight about(kg) |
1800 |
3000 |
5000 |
8000 |
10000 |
16000 |
Target Refuse type |
Burner's temperature |
Smoke's stay time |
Burning rate |
Destroying rate |
Ashes' heat decreasing rate |
Clinical refuse | ≥850 | ≥2.0 | ≥99.9 | ≥99.9 | ≥95 |
Table 3
Ordinal Numer | Refuse name | Measuring unit | GB18484-2001 |
1 | Blackness of Flue Gas | Ringelmann class | 1 |
2 | Smoke&Dust | mg/m3 | 100 |
3 | CO | mg/m3 | 100 |
4 | SO2 | mg/m3 | 400 |
5 | HF | mg/m3 | 9.0 |
6 | HCL | mg/m3 | 100 |
7 | NO2 | mg/m3 | 500 |