Hospital Medical Waste Incinerator, Small Pets Animal Crematory Incinerator, Garbage Incinerator

Product Details
Customization: Available
After-sales Service: Lifetime Technical Service
Warranty: 1 Year
Manufacturer/Factory, Trading Company

360° Virtual Tour

Diamond Member Since 2023

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
to see all verified strength labels (20)
  • Hospital Medical Waste Incinerator, Small Pets Animal Crematory Incinerator, Garbage Incinerator
  • Hospital Medical Waste Incinerator, Small Pets Animal Crematory Incinerator, Garbage Incinerator
  • Hospital Medical Waste Incinerator, Small Pets Animal Crematory Incinerator, Garbage Incinerator
  • Hospital Medical Waste Incinerator, Small Pets Animal Crematory Incinerator, Garbage Incinerator
  • Hospital Medical Waste Incinerator, Small Pets Animal Crematory Incinerator, Garbage Incinerator
  • Hospital Medical Waste Incinerator, Small Pets Animal Crematory Incinerator, Garbage Incinerator
Find Similar Products

Basic Info.

Model NO.
LDF 20 LDF 30 LDF-50LDF-100 LDF-150 LDF-300
Condition
New
Certification
ISO, CE
Automation
Semi-Automatic
Screw
Multi-Screw
Treatment
Burning
Incineration Removal Rate
99.9%
Incinerator Fuel
Natural Gas, Diesel, Liquefied Petroleum Gas,
Voltage
220V50Hz
Incinerator Structure
Double Chamber Incineration
Waste Can Burn
Hospital Medical Care, Animal Carcasses, Industria
Colour
Customer Demand
Advantage
Environmental Protection
Waste Type
Mixed Waste
Productive Capacity
Sets/Month
Transport Package
Containers Are Packed in PE Films or Wooden Cases
Specification
20-500 kg per lot
Trademark
LD
Origin
Dezhou in Shandong Province
HS Code
8417809090
Production Capacity
500 Sets/Year

Product Description

 The main characteristics and scope of application of incinerator
LDF series medical waste incinerator is a medical waste incineration equipment with independent intellectual property rights developed by Shandong Lvdu Environmental Equipment Co., LTD., which introduced the world's advanced medical incinerator technology and organized technical experts to tackle key problems. The equipment has the characteristics of full closure, small size, high incineration efficiency, reasonable process, leading technology, and high degree of harmfulness. It is an ideal garbage disposal equipment for all kinds of hospitals, hotels, stations, large commercial institutions, enterprises, and public institutions. Main features:
1. Gasification incineration technology is applied to the incineration of syringes, drip containers and other medical equipment as well as all kinds of paper waste, bandages, absorbent cotton, all kinds of medical sewage and all kinds of waste discharged by hospitals and medical institutions.
2. Using gasification incineration method, the waste generated every day can be incinerated once.
3. The use of gasification incineration, mixed incineration, burnout treatment and other technologies, so that the exhaust smoke, soot content is lower than the national emission standards.
4. Fully enclosed operation, suitable for the treatment of infectious medical waste, to avoid secondary pollution.
5. Small size, small footprint.
6. The series of incinerators are divided into fuel oil and gas, and users can use different types according to their needs.
Technical characteristics of incinerators
LDF series medical waste incinerator adopts the most advanced incineration method of primary pyrolysis gasification + wind cocombustion + secondary incineration + burnout treatment. The design of the primary combustion chamber of the incinerator adopts the gasification incineration technology to make the temperature in the incinerator shift from 200ºC to 400ºC, and the waste will not produce frit, slag, sintering and other problems in the incineration process. Compared with direct combustion furnace and other furnaces, the dust production of gasification incinerator is very small, and secondary combustion burners and circumferential air supply devices are installed in the secondary mixed incineration chamber. At high temperatures, the combustible gas in the flue gas can be fully burned, and the gas produced by the gasifier can be fully mixed with the air to burn efficiently, preventing the carbon in the gas flame from escaping and the occurrence of late burning. When the flue gas enters the high temperature burnout chamber, due to the use of tangential entry and tangential entry of combustion-supporting air, the flue gas can be fully burned again in the burnout chamber, and the use of rotating airflow for flue gas dust removal. The residence time of the incinerator flue gas in the furnace is greater than 2 seconds, so that the combustible gas in the flue gas and the combustible matter in the fly ash are completely incinerated. The upper part of the incinerator is equipped with dry tail gas purification equipment to adsorb hydrogen chloride and sulfur oxides produced in the incineration, and the odor and other components in the flue gas are decomposed at high temperature. The flue gas purification system is equipped with calcium hydroxide filter brick for neutralizing reaction with acid gas to achieve the purpose of adsorption of acid gas and purification of tail gas. The harmful components in the flue gas are reduced to the national "Hazardous Waste incineration Pollution Control Standard (GB18484-2001)" and other standards below the specified value.
The operation control of the incinerator adopts automatic program control, which reduces the labor degree of the workers, and the design of the furnace door and ash cleaning door adopts the fully sealed structure in the form of the child and the mother. During the incineration, the furnace is completely isolated from the outside of the furnace, forming negative pressure combustion, which eliminates the possibility of secondary pollution, especially the treatment of infectious dangerous medical waste, which can highlight its unique advantages.


Technical parameters of LDF series incinerators
type
project
LDF-20 LDF-30 LDF-50 LDF-150 LDF-300 LDF-500

Incineration capacity
10-20kg/times(can be burned 3-6times per day) 20-30kg/times(can be burned 3-6times per day) 30-50kg/times(can be burned 3-6times per day) 100-150kg/times(can be burned 3-6times per day) 200-300kg/times(can be burned 3-6times per day) 300-500kg/times(can be burned 3-6times per day)
Incineration size
m(L×H×B)

1.6×1.3×1.75

1.45×0.9×2.45

1.8×1.15×3

2×1.5×3.5

2.25×1.6×3.8

3×2×4.8
Garbage inlet size(mm)
380×480

480×600

620×800

760×960

900×1100

1080×1280

chimney(External diametermm)

Ø280

Ø280

Ø280

Ø300

Ø400

Ø460

Induced draft fan

0.25kw

0.37kw

0.37kw

0.5kw

0.75kw

0.75kw
(Two sets)
 

Burner#1
power0.11kw
Fuel consumption4-6kg/h
power0.11kw
Fuel consumption4-6kg/h
power0.11kw,Fuel
consumption4-10kg/h
power0.11kw,
Fuel
consumption4-10kg/h
power0.22kw,
Fuel
consumption7-14kg/h
power0.22kw,
Fuel
consumption7-14kg/h

Burner#2
power0.11kw
Fuel consumption4-10kg/h
power0.11kw
Fuel consumption7-14kg/h
power0.11kw
Fuel consumption7-14kg/h
power0.22kw
Fuel consumption10-20kg/h
power0.37kw
Fuel consumption14-26kg/h
power0.37kw
Fuel consumption20-30kg/h

Running
voltage

220V

220V

220V

220V

220V

220V

Weight about(kgHospital Medical Waste Incinerator, Small Pets Animal Crematory Incinerator, Garbage Incinerator)

1800

3000

5000

8000

10000

16000

 

notes:Technical parameters are subject to change without notice.



Table 2
 
    Target

Refuse type
Burner's
temperature
Smoke's
stay time
Burning
rate
Destroying
rate
Ashes' heat
decreasing rate
Clinical refuse 850 ≥2.0 ≥99.9 ≥99.9 95



Incinerator loading diagram


Hospital Medical Waste Incinerator, Small Pets Animal Crematory Incinerator, Garbage Incinerator
Hospital Medical Waste Incinerator, Small Pets Animal Crematory Incinerator, Garbage Incinerator
The customer is burning garbageHospital Medical Waste Incinerator, Small Pets Animal Crematory Incinerator, Garbage IncineratorHospital Medical Waste Incinerator, Small Pets Animal Crematory Incinerator, Garbage IncineratorHospital Medical Waste Incinerator, Small Pets Animal Crematory Incinerator, Garbage IncineratorHospital Medical Waste Incinerator, Small Pets Animal Crematory Incinerator, Garbage Incinerator
Table 3
Ordinal Numer Refuse name Measuring unit GB18484-2001
1 Blackness of Flue Gas Ringelmann class 1
2 Smoke&Dust mg/m3 100
3 CO mg/m3 100
4 SO2 mg/m3 400
5 HF mg/m3 9.0
6 HCL mg/m3 100
7 NO2 mg/m3 500




Company honorHospital Medical Waste Incinerator, Small Pets Animal Crematory Incinerator, Garbage IncineratorHospital Medical Waste Incinerator, Small Pets Animal Crematory Incinerator, Garbage IncineratorHospital Medical Waste Incinerator, Small Pets Animal Crematory Incinerator, Garbage IncineratorHospital Medical Waste Incinerator, Small Pets Animal Crematory Incinerator, Garbage Incinerator
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier