Disinfection Treatment of Medical Wastewater,

Product Details
Customization: Available
After-sales Service: 1 Year
Warranty: 1 Year
Manufacturer/Factory, Trading Company

360° Virtual Tour

Diamond Member Since 2023

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
to see all verified strength labels (20)
  • Disinfection Treatment of Medical Wastewater,
  • Disinfection Treatment of Medical Wastewater,
  • Disinfection Treatment of Medical Wastewater,
  • Disinfection Treatment of Medical Wastewater,
  • Disinfection Treatment of Medical Wastewater,
  • Disinfection Treatment of Medical Wastewater,
Find Similar Products

Basic Info.

Model NO.
10-1000 cubic meters per day
Type
Sludge Dewatering Machine
Usage
Industrial, Agriculture, Hospital
Voltage
Can Be Customized as Client Request
Service Life
20 Years
Material Quality
Carbon Steel or Stainless Steel
Installation Method
Above Ground or Underground
Transport Package
Export Packaging
Trademark
LUDU
Origin
Shandong China
HS Code
8421219990
Production Capacity
2000 Pieces Year

Product Description

With economic and population growth, nature pollution was more and more valued by people, based on summarizing domestic sewage treatment plant operating experience at home and abroad ,combine our company's scientific achievements and engineering practice, designed one whole set organic wastewater treatment plant which can be buried underground or ground, it was adopt carbon steel lining with anti-corrosion painting       main     material     compact sewage treatment plant, its main purpose is make  domestic  sewage  and  similar  industrial  organic  sewage  to  achieve  user's emissions standards after treatment by this plant, its mainly used in treating domestic sewage in Residential area (including villa district) , senior hotel,complex office and various of public hospital buildings, final cleaning water quality can achieve national emission standard after treatment. The whole set plant can be buried underground or lay  on the  ground,  so  it  is known  as  "compact  sewage  treatment plant."  it  adopt international advanced biological treatment processes, set     removing BOD5, COD, NH3-N together, with the advantage  of Technical performance  stable and reliable, good treatment effect, save investment, small occupy area, and easy maintenance.
1. 1 Feature:
1. 11 Its installation manner can be underground or ground, the surface above plant can be used as green or other land, no housing and heating, insulation.
1. 12 The contact oxidation process adopt plug-flow bio-contact oxidation, treatment effect better than completely mixed or two grade series completely mixed biological contact oxidation pool. And smaller than activated sludge tank, strong adaptability to water quality , resistance to shock loading performance, effluent water quality stability, it won't produce  sludge bulking. Tank body  equip new  flexible three-dimensional biological carrier , large surface area, microbial easy to hang film and stripping, in same organic load condition, high removal rate of organic matter, improve oxygen solubility in water.
1. 13 The biochemical tank adopt biological contact oxidation, its biological carrier
 
volume loading relatively low volume , microbial stay in self-oxidation section, less sludge production, only each three months    or more days discharge one time sludge, (using suction truck or dehydration cake transport away).
1. 14 control manner have PLC fully automatic control and manual control , electric parts setting failure alarm, safe and reliable operation, usually no need special expert management generally, only timely maintenance small parts of plant.
1.2 Scope ofApplication
1.21 Hotels, restaurants, nursing homes, hospitals.
1.22 Residential areas, village, town ,Villa,shelter etc
1.23 Stations, airports, port terminals and ship.
1.24 Factories, mines,  tourist, scenic.
1.25 All kinds of industrial wastewater similar with domestic sewage.

2 Design scope and Design water quality and quantity

This  design  mainly  for  wastewater  treatment  process,  structure  and  related equipment to carry on the design.
2. 1 Design water quantity
The wastewater treatment engineering design for the hotel sewage, the treatment of processing water is10m3 /d, sewage treatment , The sewage treatment process has the,capability of shock load resistance.
2.2 Design the water quality of influent and effluent
Influent water quality designed according to the following table:
Table  1- 1:  Influent  water  quality
Unit :mg/L

 


Influent


A&G


BOD5


SST

Ammomia
nitrogen


Total phosphorus
 
Concentration 150 300 300 60    15
 
Effluent water quality standard,as follows:
3 Process selection and brief introduction

3. 1 Scheme outlined
Traditional  sewage  treatment  process  can  divide  into  biological  membrane   manner  and  activated  sludge  manner,  biological  membrane  suitable  to  small  wa ter  volume,  steady  water  quality,  low  concentration  sewage  water  quality,  better
system  commission.  Steady  back  operation,  better  operability.  Sewage  water  q uality  set  as  traditional  routine:  CODCr  ≤  620mg/l ,BOD5  ≤536mg/l,BOD5/CO Dcr  >0.5,  better  biodegradability,  due  to  ammonia  nitrogen  and  organism  conte nt  is  high,  especially  organic  nitrogen,  when  biological  degradation  organism,  t he  organic  nitrogen  will  be  express  in  the  form  of ammonia  nitrogen,  ammonia
nitrogen  is  a  key  pollution  control  index,  so  such  sewage  treatment  adopt  ano xia  oxic  A/O  biological  contact  oxidation  process,  so  the  biochemical  tank  divi de  into  A  grade  anoxia  tank  and  O  grade  oxidation  tank  two  parts.
The  sewage  will  first  pass  screen  channel.In  this  channel,part  of floating  s olid  and  suspended  matter  will  be  removed.Then  flow  into  Equalize  Tank,  due
to  the  sewage  flow  rate  was  different  in  each  day,  it  has  peaking  time,  so  w e  set  equalize  tank  to  balance  the  quality  and  flow  rate  of water.  Then  sewage
 
will  uniform  lifting  into  compact  sewage  treatment  plant  by  pump;  there  are  s et  2  pcs  of submersible  sewage  pump  in  equalize  tank.
The  compact  sewage  treatment  plant  includes  primary  setting  tank,anoxia  t ank,  oxidation  tank,  secondary  settling  tank  ,cleaning  water  tank  and  control  ro om  etc  six  parts.
First  enter  into  primary  settling  tank,  it  used  to  primary  remove  the  settlin g  matter  and  floats,  it  can  relieve  the  following  loading.  Then  sewage  enter  int o  anoxia  tank,  due  to  sewage  organism  content  is  high,  microorganism  in  anox ia  condition,  now  the  microorganism  is  facultative,  they  will  transform  the  orga nic  nitrogen  into  ammonia  nitrogen,  at  the  same  time,  using  organic  carbon  so urce  as  electron  donor,  to  make  the  NO2-N ,NO3-N  translate  into  N2,  and  usi ng  part  of carbon  source  and  ammonia  nitrogen  synthesis  new  cellular  material.
so  anoxia  tank  has  certain  function  of organic  matter  removal,  relieve  the  org anic  load  of follow-up  oxidation  tank,  to  benefit  to  nitrification,  and  rely  on  hi gh  concentration  organism  in  sewage,  to  finish  denitrification,  finally  eliminate   the  nitrogen  eutrophication  pollution.  By  anoxia  tank  biochemical  action,  the  se wage  still  contain  some  organism  and  higher  ammonia  nitrogen,  in  order  to  ma ke  organism  further  oxic  degradation,  at  the  same  time,  when  carbonization  ten d  to  finish,  nitrification  can  smoothly  going  on,  thus  set  O  grade  oxidation  tan k.
The  outlet  water  from  anoxia  tank  will  flow  into  oxidation  tank,  the  oxic  biochemical  treatment  rely  on  autotrophic  bacteria  finish,  they  utilize  organism  resolve  generate  inorganic  carbon  or  carbon  dioxide  in  air  as  nutrients  source,   to  make  the  ammonia  nitrogen  translate  into  NO2-N,  NO3-N,  a  part  of oxic  ta nk  outlet  water  enter  into    secondary  settling  tank  to  sediment,  another  part  ba ckflow  to  anoxia  tank  to  proceed  anoxic  tank  to  proceed  internal  recycle,  to  re alize  nitrifying  purpose.  All  equip  with  padding  in  anoxic  tank  and  oxic  tank,  the  whole  biochemical  treatment  process  all  rely  on  many  kinds  of microorgani sm  to  finish.
 
The  dissolved  oxygen  is  control  about  0.5mg/l  in  anoxia  tank,  above  2.0m g/l  oxic  tank,  air  water  ratio  12:1;  part  of outlet  water  in  oxic  tank  backflow  t o  anoxic  tank,  reflux  ratio  is  200%;  part  flow  into  secondary  settling  tank,  to   make  solid  liquid  separation;  the  outlet  water  in  settling  tank  after  solid  liquid  separation,  it  will  flow  into  cleaning  water  tank,the  fianl  water  will  discharge  a fter  make  disinfection  by  uv-sterilzier.  The  settling  sludge  in  settling  tank  will  pump  to  sludge  concentration  tank,  the  concentrated  sludge  transport  out  as  far ming  fertilizer.
Compact  sewage  treatment  plant  structure:
( 1)  Primary  settling  tank:
It  can  initial  remove  the  sediment  and  floating  matter  in  waste  water,  as  pretre atment  unit;
(2)  Anoxic  tank
In  order  to  control  the  dissolved  oxygen  in  A  grade  biochemical  tank  about  0. 5mg/l,  adopting  interval  aeration.  The  padding  in  A  grade  biochemical  tank  ad  opting  new  type  elastic  padding,  height  is  2.0m.  such  padding  with  the  advanta
ge  of no  easy  blocking,  light  weight,  big  specific  surface  area,  treatment  effect steady  etc,  easy  to  maintenance;
(3)  Oxidation  tank  with  MBR
The  O  grade  biochemical  tank  equip  with  columnar  biology  carrier  padding,  thi s  padding  specific  surface  area  is  big,  is  16-20  times  comparing  with  common
biological  padding,  keep  higher  biomass,  to  reach  the  purpose  of removing  or ganic  pollutant,  aeration  device  adopting  air  blower  and  micropore  aerator,  the oxygen  utilization  rate  is  above  30,  effective  save  operation  cost.  air  water  rati o  about  12:1.
(4)  Secondary  settling  tank
The  sewage  still  contain  large  number  of suspended  solid  after  treated  by  O  gr ade  biochemical,  in  order  to  make  the  effluent  water  SS  meet  up  discharge  sta ndard,  adopting  vertical  settling  tank  to  make  solid  liquid  separation,  1  set  ,  su

rface  load  1.0m3/mhr.  the  settling  tank  sludge  adopt  air  lifting  device  lift  to  sludge  tank,  at  the  same  time,  according  to  actual  condition  to  make  part  of sl udge  lifting  to  A  grade  biochemical  tank  to  proceed  sludge  backflow,  increase  the  sludge  concentration  in  O  grade,  improve  removal  efficiency.
(5)  control  room
Air  blower  set  in  the  air  blower  room,  equip  with  silencer.


Disinfection Treatment of Medical Wastewater,Disinfection Treatment of Medical Wastewater,Disinfection Treatment of Medical Wastewater,Disinfection Treatment of Medical Wastewater,
Disinfection Treatment of Medical Wastewater,Disinfection Treatment of Medical Wastewater,Disinfection Treatment of Medical Wastewater,

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier