High Temperature Pyrolysis Gasification Medical Waste Incinerator, Animal Carcass Incinerator

Product Details
Customization: Available
After-sales Service: Lifetime Technical Services
Warranty: 1 Year
Manufacturer/Factory, Trading Company

360° Virtual Tour

Diamond Member Since 2023

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
to see all verified strength labels (20)
  • High Temperature Pyrolysis Gasification Medical Waste Incinerator, Animal Carcass Incinerator
  • High Temperature Pyrolysis Gasification Medical Waste Incinerator, Animal Carcass Incinerator
  • High Temperature Pyrolysis Gasification Medical Waste Incinerator, Animal Carcass Incinerator
  • High Temperature Pyrolysis Gasification Medical Waste Incinerator, Animal Carcass Incinerator
  • High Temperature Pyrolysis Gasification Medical Waste Incinerator, Animal Carcass Incinerator
  • High Temperature Pyrolysis Gasification Medical Waste Incinerator, Animal Carcass Incinerator
Find Similar Products
  • Overview
  • Product Description
Overview

Basic Info.

Model NO.
LDF-20/30/50/100/150/200/300/500/600
Automation
Automatic
Screw
Multi-Screw
Treatment
Burning
Fuel
Diesel, Natural Gas,
Life
10 Years
Voltage
220V50-60Hz
Combustion Method
Dual Combustion Combustion
Material
Q235 Steel or 304 Stainless Steel
Transport Package
Naked Bags or Wooden Boxes
Specification
1.7*1.3*2.5
Trademark
lvdu
Origin
Shandong China
HS Code
8417809090
Production Capacity
2000 Pieces Year

Product Description

Product Description

 

Main Characteristics And Scope of Application
   LDF series of medical waste incinerator, produced by Shandong Lvdu environmental equipment Co., Ltd, introduced the world's most advanced medical incinerator technology, and have developed independent intellectual property rights of the gaebage icinerator processing equipment, which developed by our own technical experts and research organizations. The equipment is totally enclosed, small size, high efficiency of burning. It has reasonable process, high technology, and less hazardous.LDF series of medical waste incinerator has wide applications such as hospitals, hotels, railway stations, large commercial institutions, enterprises and institutions.
 Main features:
1. The use of gasification burning technology, can be applied to the burning of syringes, drip container and other medical devices. Also can be applied to the burning of a variety of paper-based waste materials, bandages, cotton wool, all kinds of dirt and wastes discarded by hospital and medical institutions.
2. By using of gasification incineration method, wastes generated every day can be incinerated once at a time.
3. The use of gasification burning, mixed-burning, and burn treatment technology, makes smoke and dust content lower than the state emission standards.
4.Totally enclosed operations, which applied to the handling of infectious medical wastes, avoid secondary pollution.
5.Small size , small footprints.
6.Two kinds of this series of incinerator, the oil fuel and the gas fuel, user can select different type according to the need.
High Temperature Pyrolysis Gasification Medical Waste Incinerator, Animal Carcass IncineratorHigh Temperature Pyrolysis Gasification Medical Waste Incinerator, Animal Carcass Incinerator
Model LDF-20 LDF-30 LDF-50 LDF-100 LDF-150 LDF-300 LDF-500
Burning ability(kg/hour) 10-20 20-30 40-50 80-100 150-200 200-300 400-500
Incinerator size
(L×H×B)
1.6×1.2
×1.75
1.7×1.3
×2.5
1.8×1.3
×3
2.0×1.4
×3.4
2.2×1.5
×3.5
2.4×1.6×3.8 3×2×4.8
furnace volume 0.2m³ 0.4m³ 0.6m³ 1.2m³ 1.5m³ 2.5m³ 4.0m³
Garbage entrance size(mm) 380×480 480×600 600×800 700×900 800×1000 900×1100 1080×1280
chimney(mm) Ø280×
6000
Ø280×
6000
Ø330×
9000
Ø330×
9000
Ø360×
10000
Ø400×
10000
Ø460×
12000
fan power(KW) 0.25 0.37 0.55 0.75 0.75 1.1 1.5
Burner power(KW) 0.22 0.22 0.29 0.29 0.36 0.43 0.55
oil consumption 4-6kg/h 4-6kg/h 6-10kg/h 6-10kg/h 10-15kg/h 15-20kg/h 15-25kg/h

Operate voltage(V)
220V/
380V/
50-60HZ
220V/
380V/
50-60HZ
220V/
380V/
50-60HZ
220V/
380V/
50-60HZ
220V/
380V/
50-60HZ
220V/
380V/
50-60HZ
220V/
380V/
50-60HZ
Weight(kg) 1800 3000 5000 7000 8000 10000 15000
 


High Temperature Pyrolysis Gasification Medical Waste Incinerator, Animal Carcass Incinerator
High Temperature Pyrolysis Gasification Medical Waste Incinerator, Animal Carcass Incinerator
What the LDF series Medical Wastes Incinerator used is the most advanced burning down technology, that is first burning, second burning, and burn treatment. The design of incinerator's combustion chamber use the gasified burning down technology to move the temperature in incinerator stove from 200ºC to 1100ºC. Due to this technology, there will no melt block,slag lump and sintering problems in the burning down process. Gasification and direct-fired incinerators have very little dust generated during the process, compared with other kinds of heaters and stoves. There are second burning equipment and circle-wind generator installed in the second burning combustion chamber. Under the high temperature, the flammable gas can fully burn, and also mix and burn the gas generated in gasifier with the air under high efficiency, prevented the carbon material's transgression and late burn phenomena. Because of the combustion ways like tangential entering of gas and air are used, the gas can reburn fully in the combustion chamber. And at the same time use   the circle airstream to remove the dust. The flue gas can stay in the   combustion chamber more than for 2 seconds, so the combustible substances in flammable gas and flying ashes can be burn down completely. There are dry exhaust purification equipment fixed on the  incinerator's upside, which supply the adsorption treatment of Hydrogen Chloride and Sulfur Oxides. And Ozone in the flue gas is decomposed under the high temperature. On the purpose of getting rid of the acidic gas and purifing the exhaust gas, flue gas purification system have filtration brick of Ca(OH)2, which react with acidic gas. And reduced the harmful ingredient in the to flue gas below country's"The Hazardous Wastes Burning Down Contamination Control Standard (GD18484-2020)".
High Temperature Pyrolysis Gasification Medical Waste Incinerator, Animal Carcass IncineratorHigh Temperature Pyrolysis Gasification Medical Waste Incinerator, Animal Carcass IncineratorHigh Temperature Pyrolysis Gasification Medical Waste Incinerator, Animal Carcass Incinerator
High Temperature Pyrolysis Gasification Medical Waste Incinerator, Animal Carcass IncineratorHigh Temperature Pyrolysis Gasification Medical Waste Incinerator, Animal Carcass IncineratorHigh Temperature Pyrolysis Gasification Medical Waste Incinerator, Animal Carcass IncineratorHigh Temperature Pyrolysis Gasification Medical Waste Incinerator, Animal Carcass IncineratorHigh Temperature Pyrolysis Gasification Medical Waste Incinerator, Animal Carcass IncineratorHigh Temperature Pyrolysis Gasification Medical Waste Incinerator, Animal Carcass IncineratorHigh Temperature Pyrolysis Gasification Medical Waste Incinerator, Animal Carcass Incinerator
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier