• Bioblaze 20-500: High Efficiency Natural Gas Incineration System
  • Bioblaze 20-500: High Efficiency Natural Gas Incineration System
  • Bioblaze 20-500: High Efficiency Natural Gas Incineration System
  • Bioblaze 20-500: High Efficiency Natural Gas Incineration System
  • Bioblaze 20-500: High Efficiency Natural Gas Incineration System
  • Bioblaze 20-500: High Efficiency Natural Gas Incineration System

Bioblaze 20-500: High Efficiency Natural Gas Incineration System

After-sales Service: Lifetime Technical Services
Warranty: a Year
Certification: ISO, CE
Automation: Automatic
Screw: Multi-Screw
Treatment: Burning
Customization:
Manufacturer/Factory, Trading Company

360° Virtual Tour

Diamond Member Since 2023

Suppliers with verified business licenses

Shandong, China
Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
to see all verified strength labels (20)

Basic Info.

Model NO.
LDF-20/30/50/100/150/200/300/500/600
Fuel
Diesel, Natural Gas,
Transport Package
Naked Bags or Wooden Boxes
Specification
1.7*1.3*2.5
Trademark
lvdu
Origin
Shandong China
HS Code
8417809090
Production Capacity
2000 Pieces Year

Product Description

Main Characteristics And Scope of Application
   LDF series of medical waste incinerator, produced by Shandong Lvdu environmental equipment Co., Ltd, introduced the world's most advanced medical incinerator technology, and have developed independent intellectual property rights of the gaebage icinerator processing equipment, which developed by our own technical experts and research organizations. The equipment is totally enclosed, small size, high efficiency of burning. It has reasonable process, high technology, and less hazardous.LDF series of medical waste incinerator has wide applications such as hospitals, hotels, railway stations, large commercial institutions, enterprises and institutions.
 Main features:
1. The use of gasification burning technology, can be applied to the burning of syringes, drip container and other medical devices. Also can be applied to the burning of a variety of paper-based waste materials, bandages, cotton wool, all kinds of dirt and wastes discarded by hospital and medical institutions.
2. By using of gasification incineration method, wastes generated every day can be incinerated once at a time.
3. The use of gasification burning, mixed-burning, and burn treatment technology, makes smoke and dust content lower than the state emission standards.
4.Totally enclosed operations, which applied to the handling of infectious medical wastes, avoid secondary pollution.
5.Small size , small footprints.
6.Two kinds of this series of incinerator, the oil fuel and the gas fuel, user can select different type according to the need.
Bioblaze 20-500: High Efficiency Natural Gas Incineration SystemBioblaze 20-500: High Efficiency Natural Gas Incineration SystemBioblaze 20-500: High Efficiency Natural Gas Incineration System
Bioblaze 20-500: High Efficiency Natural Gas Incineration System
What the LDF series Medical Wastes Incinerator used is the most advanced burning down technology, that is first burning, second burning, and burn treatment. The design of incinerator's combustion chamber use the gasified burning down technology to move the temperature in incinerator stove from 200ºC to 1100ºC. Due to this technology, there will no melt block,slag lump and sintering problems in the burning down process. Gasification and direct-fired incinerators have very little dust generated during the process, compared with other kinds of heaters and stoves. There are second burning equipment and circle-wind generator installed in the second burning combustion chamber. Under the high temperature, the flammable gas can fully burn, and also mix and burn the gas generated in gasifier with the air under high efficiency, prevented the carbon material's transgression and late burn phenomena. Because of the combustion ways like tangential entering of gas and air are used, the gas can reburn fully in the combustion chamber. And at the same time use   the circle airstream to remove the dust. The flue gas can stay in the   combustion chamber more than for 2 seconds, so the combustible substances in flammable gas and flying ashes can be burn down completely. There are dry exhaust purification equipment fixed on the  incinerator's upside, which supply the adsorption treatment of Hydrogen Chloride and Sulfur Oxides. And Ozone in the flue gas is decomposed under the high temperature. On the purpose of getting rid of the acidic gas and purifing the exhaust gas, flue gas purification system have filtration brick of Ca(OH)2, which react with acidic gas. And reduced the harmful ingredient in the to flue gas below country's"The Hazardous Wastes Burning Down Contamination Control Standard (GD18484-2020)".
Bioblaze 20-500: High Efficiency Natural Gas Incineration SystemBioblaze 20-500: High Efficiency Natural Gas Incineration SystemBioblaze 20-500: High Efficiency Natural Gas Incineration SystemBioblaze 20-500: High Efficiency Natural Gas Incineration SystemBioblaze 20-500: High Efficiency Natural Gas Incineration SystemBioblaze 20-500: High Efficiency Natural Gas Incineration SystemBioblaze 20-500: High Efficiency Natural Gas Incineration System
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2023

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company
Export Year
2013-05-29
OEM/ODM Availability
Yes